Single phase HV hybrid inverter 5-12kW

Hybrid | Single Phase | High Voltage

5/8/10/12 kW

Product Features

120% Off-grid Output Overload

SiC Technology

2 Independent Battery Ports for Mixture Use of Old & New Battery

AFCI/PID Function

Support OTA

Max. PV Input Current 20A

3 MPPTs

165mm Ultra-thin

Model Name Isuna D5K-SH Isuna D8K-SH Isuna D10K-SH Isuna D12K-SH
Off-grid Output
Nominal Output Power5kW8kW10kW12kW
Max. Output Current26A42A52A62A
Peak Power & Duration6kW-60s9.6kW-60s12kW-60s14.4kW-60s
Nominal Output VoltageL/N/PE, 220V/230V/240V
Generator PortSupport
On-grid Parameter
Nominal Output Power5kW8kW10kW12kW
Max. Output Power6kW9.6kW12kW14.4kW
Max. Input Power from Grid7.5kW12kW15kW18kW
Max. Input Current from Grid32.5A52A65A80A
Max. Output Current26A42A52A62A
Nominal VoltageL/N/PE, 220V/230V/240V
Grid Voltage Range185–276V(P2N)
PV Input
Max. Input Power7500Wp12000Wp15000Wp18000Wp
Max. Input Voltage1000V
Number of MPPT3
Max. Input String Per MPPT1/1/1
MPPT Voltage Range160–960V
Nominal Voltage600V
Starting Voltage160V
Max. Input Current20A/20A/20A
Short-Circuit Current24A/24A/24A
Battery Parameter
Battery TypeLithium-ion / Lead-Acid / Sodium-ion (Optional)
Number of Battery Input2
Battery Voltage Range125–800V
Max. Charging/Discharging Current25A/25A25A/25A25A/25A25A/25A
Peak Charging/Discharging Current & Duration35A/35A-60s
Communication PortRS485/CAN
Efficiency
Max. Efficiency98.20%
European Efficiency97.70%
Max. Battery Charging/Discharging Efficiency96.0%
General Data
Size (W*H*D)400mm * 550mm * 165mm
Weight28kg
Noise<45dB
Operating Temperature-25°C~+60°C (>45°C Derating)
Cooling MethodSmart Cooling
Protection GradeIP65
TopologyNon-Isolated
MonitoringWIFI/4G/Bluetooth/RS485
Protection DC Switch; Reverse Polarity Protection (BAT); AC Overvoltage/Overcurrent/Short Circuit Protection; Anti-islanding Protection; Residual Current Monitoring; Insulation Resistance Detection; Surge Protection; DC Type II / AC Type III; AFCI (Optional); PID (Optional)
Certification
CE-LVDIEC62109-1&2, IEC 62477-1
CE-EMC EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN 61000-4-16, EN 61000-4-18, EN 61000-4-29
Grid VDE-AR-N 4105; VDE 0126-1-1 EN 50549-1; G98, G100; CEI 0-21; AS/NZS4777.2 NRS 097-2-1
Scroll to Top