Three phase HV hybrid inverter 10-20kW

Hybrid | Three Phase | High Voltage

10/12/15/18/20kW

Product Features

Support 100%
Three Phase Unbalance

SiC Technology
98.2% Efficiency

15 Units Parallel

Support AC Couple

Supports 130-200%
Instant Overload (60s)

1.5 Times DC/AC Ratio

Max. Grid Current Ratio 1:1.8

2 Independent Battery Ports
for Mixture Use of Old & New Battery

Model Name Isuna 10000T Isuna 12000T Isuna 15000T Isuna 18000T Isuna 20000T
Off-grid Output
Nominal Output Power 10kW 12kW 15kW 18kW 20kW
Nominal Voltage 3/N/PE, 220/380Vac; 230/400Vac
Nominal Frequency 50/60Hz
Output THDv <3%
Nominal Output Current 15A 18A 22.5A 27A 30A
On-grid Parameter
Nominal Output Power 10kW 12kW 15kW 18kW 20kW
Max. Output Power 11kVA 13.2kVA 16.5kVA 19.8kVA 22kVA
Max. Input Power From Grid 20kVA 24kVA kV30A 36kVA 40kVA
Max. Output Current 29A 35A 44A 52A 58A
Max. Input Current from Grid 16A 20A 24A 29A 32A
Nominal Grid Voltage 3/N/PE, 220/380V; 230/400V; 240/415V
Grid Voltage Range 184-276V/320-480V
PV Input
Max. Input Power 20000Wp 24000Wp 30000Wp 30000Wp 30000Wp
Max. Input Voltage 1000V
Number of MPPTS 2
Max. Input Strings per MPPT 2
MPPT Voltage Range 130-960V
Full Load MPPT Voltage Range 250-850V 290-850V 350-850V 410-850V 450-850V
Nominal Input Voltage 600V
Starting Voltage 200V
Max. Input Current 25A/25A
Short-Circuit Current 30A/30A
Battery Parameter
Battery Type Lithium-ion/Lead-Acid (Optional)
Number of Battery Input 2
Battery Voltage Range 125-800V
Full Load Battery Voltage Range 210-800V 250-800V 300-800V 360-800V 400-800V
Peak Charging/Discharging Current 35A+35A(60s)
Max. Charging/ Discharging Current 25A + 25A
Efficiency
Max. Efficiency 98.20%
European Efficiency 97.70%
Max. Battery Charging/ Discharging Efficiency 97.80%
General Data
Size (W*H*D) 573mm*509mm*219mm
Weight 35kg
Noise <45dB(A)
Operating Temperature Range -25°C ~ +60°C
Cooling Method Air Cooling
Ingress Protection Grade IP65
Communication Port RS485/CAN/DRY contact/Parallel port
Monitoring LED/APP(WiFi/4G)/Bluetooth
Protection DC Switch; AC Overvoltage Protection; AC Overcurrent Protection; AC Short Circuit Protection; Anti-islanding Protection; Insulation Current Monitoring; Residual Current Monitoring Unit; Surge Protection; Reverse Polarity Protection (PV&Battery); Lightning Protection
Certification
CE_LVD IEC 62109-1, IEC 62109-2, EN 62109-1, EN 62109-2, IEC62477-1
CE_EMC EN61000-6-1, EN61000-6-2, EN61000-6-4, EN 62920
Grid VDE-AR-N 4105, C10/C11:2019, CEI 0-21, EN50549-1, NRS 097-2-1, NRS 097-2-2, NTS 2.1 AS4777.2:2020+Amd1:2021, PEA, MEA, IEC 62116, IEC 61727, IEC 63116, nc rfG
Scroll to Top